Buy Fluke 1507, Insulation Resistance Tester 0.01 MΩ to 10 GΩ in UAE

Fluke 1507, Insulation Resistance Tester 0.01 MΩ to 10 GΩ

Current Price ,Not Good

3,180AED

3,200
Buy Now Amazon Sellers
  • Lowest Price 1,328
  • Highest Price 3,200
  • Recent Price Drop -0.6%

Fluke 1507, Insulation Resistance Tester 0.01 MΩ to 10 GΩ Details

Features: Insulation Test Range: 1507: 0.01 MΩ To 10 GΩ Insulation Test Voltages: 1507: 50 V, 100 V, 250 V, 500 V, 1000 V Save Both Time And Money With Automatic Calculation Of Polarization Index And Dielectric Absorption Ratio Make Repetitive Tests Simple And Easy With The 1507’S Compare (Pass/Fail) Function Repetitive Or Hard-To-Reach Testing Is Easy With The Remote Test Probe Live Circuit Detection Prevents Insulation Test If Voltage > 30 V Is Detected For Added User Protection Auto-Discharge Of Capacitive Voltage For Added User Protection Ac/Dc Voltage: 0.1 V To 600 V 200 Ma Continuity Resistance: 0.01 Ω To 20.00 KΩ Save Battery Power With Auto Power Off Read Measurements Easily With Large, Backlit Display Cat Iv 600 V Overvoltage Category Rating For Added User Protection Ac/Dc Voltage Measurement Accuracy Range 600.0 V Resolution 0.1 V 50 Hz To 400 Hz ± (% Of Rdg Digits) ± (2 % 3) Input Impedance 3 Mω (Nominal), 60 Db At Dc, 50 Or 60 Hz Overload Protection 600 V Rms Or Dc Earth Bond Resistance Measurement Range/Resolution 20.00 Ω 0.01 Ω 200.0 Ω 0.1 Ω 2000 Ω 1.0 Ω 20.00 Kω 0.01 Kω Accuracy ± (1.5 % 3) Overload Protection 2 V Rms Or Dc Open Circuit Test Voltage > 4.0 V, 200.0 Ma Insulation Specifications Measurement Range 0.01 Mω To 10 Gω Test Voltage 50 V, 100 V, 250 V, 500 V, 1000 V Test Voltage Accuracy 20 %, - 0 % Short Circuit Current 1 Ma Nominal Auto Discharge Discharge Time 30 V Prior To Initialization Of Test Maximum Capacitive Load Operable With Up To 1 µf Load Measure Accuracy: 50 V: ±(3 % 5) 100 V: ±(3 % 5) 250 V: ±(1.5 % 5) 500 V: ±(1.5 % 5) 1000 V: ±(1.5 % 5) To 2000 Mω, ±(10 % 3) Above 2000 Mω General Specifications Maximum Voltage Applied To Any Terminal: 600 V Ac Rms Or Dc Storage Temperature -40 °C To 60 °C (-40 °F To 140 °F) Operating Temperature -20 °C To 55 °C (-4 °F To 131 °F) Temperature Coefficient 0.05 X (Specified Accuracy) Per °C For Temperatures 28 °C ( 82 °F) Relative Humidity 0 % To 95 % @ 10 °C To 30 °C (50 °F To 86 °F) 0 % To 75 % @ 30 °C To 40 °C (86 °F To 104 °F) 0 % To 40 % @ 40 °C To 55 °C (104 °F To 131 °F) Vibration Random, 2 G, 5-500 Hz Per Mil-Prf-28800F, Class 2 Instrument Shock 1 Meter Drop Per Iec 61010-1 2Nd Edition (1 Meter Drop Test, Six Sides, Oak Floor) Electromagnetic Compatibility: In An Rf Field Of 3 V/M, Accuracy = Specified Accuracy (En 61326-1:1997) Safety Complies With Ansi/Isa 82.02.01 (61010-1) 2004, Can/Csa-C22.2 No. 61010-1-04, And Iec/En 61010-1 2Nd Edition For Measurement Category Iv 600 V (Cat Iv) Certifications: Csa Per Standard Csa/Can C22.2 No. 61010.1-04; Tuv Per Standard Iec/En 61010-1 2Nd Edition Batteries Four Aa Batteries (Neda 15A Or Iec Lr6)