3,180AED
3,200-
Lowest Price 1,328
-
Highest Price 3,200
-
Recent Price Drop -0.6%
3,180AED
3,200
Features: Insulation Test Range: 1507: 0.01 MΩ To 10 GΩ Insulation Test Voltages: 1507: 50 V, 100 V, 250 V, 500 V, 1000 V Save Both Time And Money With Automatic Calculation Of Polarization Index And Dielectric Absorption Ratio Make Repetitive Tests Simple And Easy With The 1507’S Compare (Pass/Fail) Function Repetitive Or Hard-To-Reach Testing Is Easy With The Remote Test Probe Live Circuit Detection Prevents Insulation Test If Voltage > 30 V Is Detected For Added User Protection Auto-Discharge Of Capacitive Voltage For Added User Protection Ac/Dc Voltage: 0.1 V To 600 V 200 Ma Continuity Resistance: 0.01 Ω To 20.00 KΩ Save Battery Power With Auto Power Off Read Measurements Easily With Large, Backlit Display Cat Iv 600 V Overvoltage Category Rating For Added User Protection Ac/Dc Voltage Measurement Accuracy Range 600.0 V Resolution 0.1 V 50 Hz To 400 Hz ± (% Of Rdg Digits) ± (2 % 3) Input Impedance 3 Mω (Nominal), 60 Db At Dc, 50 Or 60 Hz Overload Protection 600 V Rms Or Dc Earth Bond Resistance Measurement Range/Resolution 20.00 Ω 0.01 Ω 200.0 Ω 0.1 Ω 2000 Ω 1.0 Ω 20.00 Kω 0.01 Kω Accuracy ± (1.5 % 3) Overload Protection 2 V Rms Or Dc Open Circuit Test Voltage > 4.0 V, 200.0 Ma Insulation Specifications Measurement Range 0.01 Mω To 10 Gω Test Voltage 50 V, 100 V, 250 V, 500 V, 1000 V Test Voltage Accuracy 20 %, - 0 % Short Circuit Current 1 Ma Nominal Auto Discharge Discharge Time 30 V Prior To Initialization Of Test Maximum Capacitive Load Operable With Up To 1 µf Load Measure Accuracy: 50 V: ±(3 % 5) 100 V: ±(3 % 5) 250 V: ±(1.5 % 5) 500 V: ±(1.5 % 5) 1000 V: ±(1.5 % 5) To 2000 Mω, ±(10 % 3) Above 2000 Mω General Specifications Maximum Voltage Applied To Any Terminal: 600 V Ac Rms Or Dc Storage Temperature -40 °C To 60 °C (-40 °F To 140 °F) Operating Temperature -20 °C To 55 °C (-4 °F To 131 °F) Temperature Coefficient 0.05 X (Specified Accuracy) Per °C For Temperatures 28 °C ( 82 °F) Relative Humidity 0 % To 95 % @ 10 °C To 30 °C (50 °F To 86 °F) 0 % To 75 % @ 30 °C To 40 °C (86 °F To 104 °F) 0 % To 40 % @ 40 °C To 55 °C (104 °F To 131 °F) Vibration Random, 2 G, 5-500 Hz Per Mil-Prf-28800F, Class 2 Instrument Shock 1 Meter Drop Per Iec 61010-1 2Nd Edition (1 Meter Drop Test, Six Sides, Oak Floor) Electromagnetic Compatibility: In An Rf Field Of 3 V/M, Accuracy = Specified Accuracy (En 61326-1:1997) Safety Complies With Ansi/Isa 82.02.01 (61010-1) 2004, Can/Csa-C22.2 No. 61010-1-04, And Iec/En 61010-1 2Nd Edition For Measurement Category Iv 600 V (Cat Iv) Certifications: Csa Per Standard Csa/Can C22.2 No. 61010.1-04; Tuv Per Standard Iec/En 61010-1 2Nd Edition Batteries Four Aa Batteries (Neda 15A Or Iec Lr6)